CUBIC 2 PRO. FR NOTICE D'INSTALLATION. UK INSTALLATION INSTRUCTIONS. DE INSTALLATIONSHINWEISE. IT STRUZIONI PER L'. The SANICUBIC® Pro tank is fitted with 2 dip tubes; one tube controls motor operation, and the other one Instructions only for qualified professional specialists. UK INSTALLATION INSTRUCTIONS . tored and are given the necessary instructions for using the SANICUBIC® 2 Classic and SANICUBIC® 2 Pro are.

Author:CASIMIRA BRANKOVICH
Language:English, Spanish, Hindi
Country:Benin
Genre:Science & Research
Pages:514
Published (Last):22.10.2015
ISBN:877-9-72344-216-2
Distribution:Free* [*Sign up for free]
Uploaded by: HILDEGARD

58934 downloads 167450 Views 23.31MB PDF Size Report


Sanicubic 2 Pro Pdf

Sanicubic 2 Pro product reference: ​The Sanicubic 2 Pro is a high performance macerator pump for commercial use. Contains two separate, load. 2. The SFA Group as inventor, designer and manufacturer, has been a major actor in France's and world's sanitary appliances 17 | SANICOMPACT® Pro SANICUBIC® 2 Pro. 41 | SANICUBIC® 2 XL indicated in the instructions. 1. SANICUBIC XL. Ref /2. SANICUBIC 2. CLASSIC Ref SANICUBIC 2 PRO. Ref SANICUBIC 1. Ref /1. SANICOM 2. Ref /2. SANICOM 1. Ref SANIBEST PRO. Ref SANISPEED. Ref indicated in the instructions.

Maugal The system sends a high-frequency overload signal to the remote alarm unit Fitted with a remote alarm module that transmits a visible and audible alarm [HF link] Inlet diameter mm for WC waste, 40mm for waste water Two alarms — one unit mounted, one remote Technical Specifications: The Sanicubic 2 Pro has four inlets, the centre height of inlets sanicjbic mm and it discharges through 50 mm pipework. The Sanicubic 2 Pro also features an inbuilt dual alarm system. For complete information on returns, click here. Dimensions Height x Width x Depth mm: They each take turns handling the wastewater so that neither is more heavily used over time than the other. Description Data sheet Complementary We do not sell spares and therefore, prro ask you to contact Saniflo technical team for spare. Our website uses cookies to improve your browsing experience. JavaScript seems to be disabled in your browser. It contains two separate, load balanced pumps with high performance macerating systems lro will operate alternatively.

Regarding supply of pressurized oil for the electro-hydraulic control of the combustion process in a large engine, ruggedness and a high level of efficiency are the critical factors:.

Continuous working pressure up to bar, the instantaneous maximum working pressure up to bar. Machinery Construction Machinery Parts. As well as from standard, nonstandard. Service kit, swing circle, engine hood, swive l joint, fuel tank, filter, boom, arm, bucket etc.

From Please enter Mobile Number. Equivalent rexroth variable pumpsa4vso hydraulic pump. It is designed for stationary or mobile applications.

Quantity The minimum purchase order quantity for the product is 1. The data are kept safe inside the back-office and serve solely as statistical data for improving rexrogh services and products.

You might also like: PROSTATISMO PDF

Contract factories with more than 10 years of experience 3. If you need to make a 90 degree turn you can accomplish this with two, 45 degree turns. We recommend placing a ball-valve at the top of the flex line so you can isolate the pump if need be.

This is one of the easiest parts of the entire installation. The water supply can also come from a bathroom on the other side of the wall or anything similar.

Install the included discharge elbow and set the discharge piping.

SANICUBIC 2 CLASSIC

Note there is a small hole in the top of some units. Because Saniflo is the global leader of macerating upflush toilets, they manufacture them to work everywhere. This small vent hole is not used in the United States. If you have a unit with a small ventilation hole, you will find a small plastic plug in with your unit. Simply place the plug in the hole. This will keep odors from coming into your living space.

Saniflo Sanicubic 2 Pro 6102 Pro Heavy Duty Macerator

Vent the System and Attach the Toilet The final step in the installation process is to vent the system and attach the toilet.

Remember that you can vent the system anywhere you choose, as long as it has adequate airflow and adheres to your local building codes.

Keep in mind the SaniCompact and SaniStar do not require ventilation. Finally, attach the toilet to the pump or extension pipe by connecting the toilet to the smaller end of the gasket, and the pump to the larger, flexible side of the gasket. Secure the pump and toilet to the floor you already installed the rubber feet, right?

Hand-tighten the water supply and — voila!

SANICOMPACT Silence ECO+

Saniflo Installation Considerations Want to make your Saniflo installation process even simpler? Take these things into consideration as you finish the system: Ensure the Pipes are Freeze-Proof.

To help the Saniflo pump work as well as possible, limit bends and elbows in your discharge pipe. Ideally, any bends should be less than 45 degrees, and the pipe should be as straight as possible. Support Your Pipes. To help your system last as long as possible, support all your Saniflo pipes according to manufacturer recommendations.

Downloading installation instructions for SFA products

This helps decrease the likelihood of blockages and backups and extends the lifespan of your system. To exit programming mode: Do nothing for several seconds Note : Duration of operation varies according to the cycle chosen. Operating wash basin: Please make sure that the wash basin tap draining into the sanicompact is properly shut off after usage and not dripping.

Insufficient water supply flow The stopcock is closed The solenoid valve 28 is faulty Insufficient water supply flow The valve flap on the siphon 23 is leaking The drain height is too great. In the event of prolonged absence it is essential to turn off the water supply to protect the installation against sub zero temperatures. Disconnect the macerator power supply,.

Carry out the operation once every 3 months on average, but the frequency may need to be changed depending on the hardness of the water.

Restore the electrical supply and check the electrical power supply Otherwise, ask an approved repair agent to intervene Clean the solenoid valve filter Modify the installation Open the stopcock Consult the SFA customer service Increase the rinsing time programming Clean or replace the valve flap on the siphon 23 Modify the installation Clean or replace the non-return valve Remove the foreign body Otherwise, ask an approved repair agent to intervene Check the installation upstream Clean or replace the non-return valve Install a vacuum breaker Remove the foreign body Otherwise, ask an approved repair agent to intervene 7 GUARANTEE 2 year guarantee as from its date of purchase subject to correct installation and correct use.

Only the disposal of toilet paper, faecal matter, and waste water will be under guarantee. Any damage due to foreign bodies such as cotton, condoms, sanitary towels, wet wipes, food, hair, metal, wood or plastic objects, will not be under guarantee.